Flow

Fireflow and Hydrant Analysis determines the hydrant flow at a specified residual pressure and creates printable fire flow graphs and hydrant reports.
Pipe2018:KYPipe allows fire flow calculations to be made at hydrants, junctions or both. Therefore it is not necessary to include hydrants in your model to calculate fire flows since junctions can be used instead. However, incorporating hydrants allows the user to plot hydrant test data and maintain accurate and detailed hydrant records in addition to calculating fire flows. Hydrant icons can be emphasized using NFPA hydrant color codes. While other hydraulic modeling software adds pipes to account for hydrants, KYPipe does not.
The KYPipe engine can output data for a variety of situations, including:
  • Determining the pumped fire flow that will maintain a specified pressure throughout the distribution system.
  • Calculating the free flow through a hydrant nozzle into atmosphere.
  • Calculating the fire flow through a hose and nozzle connected to a hydrant.

The results are presented in a printable fire flow graph or in a detailed hydrant report.

  • Download Flow Test Calculator and enjoy it on your iPhone, iPad, and iPod touch. With determining flow rates of hydrants as well as determining if the maximum flow of the water system. I test fire pumps often and this will be very useful!
  • Hydrant flow test calculator: calculate rated capacity at 20 psi The Hydrant Flow Test Calculator measures the rated capacity at 20 psi of a fire hydrant. The rated capacity calculation is useful in determining the total water supply at a given point in the hydrant or water main.
Hydrant Flow-Pressure DataHydrant Information Maintained by the Model
The hydrant flow results will appear next to each hydrant for which an analysis was conducted.
Free
Hydrant Test Graph Example

AWWA and NFPA guidelines are used to compute the curve for available pressure as a function of flowrate using the hydrant test data as shown below.
Fire hydrant flow calculator download for windows 7

Igneus Hydrant Flow Test is a simple hydrant flow test report program capable of printing and saving professional level reports you can be proud of. Igneus Hydrant Flow Test calculates flow and pitot pressure in accordance with NFPA 291 'Recommended Practice for Fire Flow Testing and Marking of Hydrants', 2007 edition.

Default Hydrant and Hose Constant / Suction Pressure at Fire Pump Calculation

As stated, conventional fire flow analysis determines the flow that maintains the distribution system pressure at a user-specified amount, typically 20 psi. However, KYPipe also allows the user the option to determine the maximum flow which will maintain a user-specified suction pressure at the fire pump. This is necessary because in some large-capacity systems, conventional fire flow analysis may overestimate the possible fire flow, predicting fire flows too large to be delivered to the pumper at an acceptable suction pressure (e.g., > 0 psi) due to losses through the hydrant and hose.

When values are entered in the fields highlighted in the above image, a second calculation is performed to determine the maximum flow that maintains an acceptable suction pressure at the fire pump. When this figure is lower than the amount determined by the conventional approach, then the conventional approach has overestimated the potential fire flow and the secondary calculation is more realistic.

Fire Hydrant Flow Chart

Hydrant Monitor Element
A Hydrant Monitor Element allows the monitor (nozzle) to operate while connecting a hose to one of the other connections. The Hydrant/Monitor may be analyzed with up to three valves open simultaneously. The K values for the Hydrant/Monitor may be set at each individual hydrant using the Node Information Data box. The open valves may by selected in the Device Data box as shown: